• Login
    View Item 
    •   DSpace Home
    • Laboratorio Nacional de Materiales y Modelos Estructurales - UCR
    • Programa de Infraestructura del Transporte
    • Informes
    • View Item
    •   DSpace Home
    • Laboratorio Nacional de Materiales y Modelos Estructurales - UCR
    • Programa de Infraestructura del Transporte
    • Informes
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    CAPACIDAD DE SOPORTE ESTRUCTURAL DE LA RUTA NACIONAL 32

    Thumbnail
    View/Open
    LM-PI-UMP-A-004.pdf (1.933Mb)
    Date
    2013-06
    Author
    Vargas Nordcbeck, Adriana
    Leiva Villacorta, Fabricio
    Aguiar Moya, José Pablo
    Elizondo Arrieta, Fabián
    Loría Salazar, Luis Guillermo
    Metadata
    Show full item record
    Abstract
    El siguiente informe presenta los resultados de una evaluación de deflectometría realizada en la Ruta 32, en un tramo de aproximadamente 1,3 km en el sentido San José - Limón, ubicado ente el cruce de "La República" y el puente que comunica a San Juan de Tibás. Con base en los datos de deflectometría se realizó un análisis de las deflexiones y de la capacidad estructural del tramo, mediante el retrocálculo de módulos. Adicionalmente, se tomaron muestras de mezcla asfáltica y se realizaron ensayos de desempeño en el laboratorio para tener un mejor entendimiento del comportamiento de la mezcla asfáltica convencional y la mezcla modificada utilizada en el proyecto. Es importante aclarar que las muestras evaluadas como parte de este informe son limitadas y no se pretender generalizar los resultados a todo el proyecto. A si mismo, las mezclas evaluadas no deben utilizarse como sustituto a una adecuada verificación de calidad ni deben ser consideradas en los procesos de pago.
     
    The following report presents the results of a deflectometry evaluation carried out on Route 32, in a stretch of approximately 1.3 km in the direction of San José - Limón, located between "La República" junction and the bridge that connects San Juan of Tibás. Based on the deflectometry data, analysis of the deflections and the structural capacity of the section were performed, by means of the back-calculation of modules. Additionally, asphalt mix samples were taken and performance tests were made in the laboratory to obtain a better understanding of the behavior of the conventional asphalt mixture and the modified mixture used in the project. It is important to clarify that the samples evaluated as part of this report are limited and it is not intended to generalize the results to the entire project. Likewise, the mixtures evaluated should not be used as a substitute for an adequate quality check nor should they be considered in the payment processes.
     
    URI
    https://www.lanamme.ucr.ac.cr/repositorio/handle/50625112500/200
    Collections
    • Informes [1094]

     © 2018-2020  Laboratorio Nacional de Materiales y Modelos Estructurales
    Contact Us | Send Feedback | 📞 +506 2511-2500 |  ✉ direccion.lanamme@ucr.ac.cr

     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

     © 2018-2020  Laboratorio Nacional de Materiales y Modelos Estructurales
    Contact Us | Send Feedback | 📞 +506 2511-2500 |  ✉ direccion.lanamme@ucr.ac.cr