Mostrar el registro sencillo del ítem

dc.contributor.authorFonseca Chaves, Francisco
dc.contributor.authorHerra Gómez, Luis Diego
dc.date.accessioned2019-04-08T21:49:10Z
dc.date.available2019-04-08T21:49:10Z
dc.date.issued2017
dc.identifier.urihttps://www.lanamme.ucr.ac.cr/repositorio/handle/50625112500/1551
dc.description.abstractSobre las bitácoras de registro de ensayos de laboratorio: Al revisar el uso de las bitácoras de registro de información de los procedimientos de ejecución de ensayos del laboratorio remoto, se determinó que existe un sistema de control documental que permite asegurar la trazabilidad de la información de las muestras y los ensayos procesados en este laboratorio, desde la toma de datos hasta la emisión del informe final. Sobre los registros de ensayo: Se evidenció la ausencia que el registro HTL001g versión 6 del 28 de agosto de 2012 (utilizado para el gráfico de flujo - estabilidad Marshall), no aparece en la lista maestra de documentos del laboratorio lo cual puede generar un riesgo potencial de no estar sujeto al plan de gestión de calidad del laboratorio. Sobre los Certificados de Calibración y registros de verificación: Basados en los certificados de calibración y registros de verificación analizados se identificaron oportunidades de mejora, ya que se observaron algunas inconsistencias entre el plan de calibración del laboratorio remoto y los certificados aportados. Además se evidenció falta de información, sobre la ubicación del laboratorio remoto donde se encuentran ubicados los equipos, en los certificados revisados. Sobre la ejecución de los ensayos de laboratorio: Durante la testificación de ensayos el equipo auditor evidenció que el laboratorio de Vieto y Asociados realiza los ensayos de laboratorio según los procedimientos establecidos en las normas de ensayo correspondientes y las buenas prácticas de laboratorio, excepto por el caso del ensayo de determinación de la gravedad específica máxima teórica en el cual el tiempo de uso de aplicación de vacío (medido en el vacuómetro) fue mayor que el establecido en la norma. Sin embargo, después de la visita realizada al laboratorio se incorporó un controlador de tiempo.es
dc.description.abstractAbout the logbooks of laboratory tests: When reviewing the use of the logbooks of information of the procedures of execution of tests of the remote laboratory, it was determined that there is a document control system that allows to ensure the traceability of the information of the samples and the tests processed in this laboratory, from the data collection to the issuance of the final report. About the test records: It was evidenced the absence that the record HTL001g version 6 of August 28th, 2012 (used for the flow chart - Marshall stability), does not appear in the master list of laboratory documents which can generate a risk potential not to be subject to the laboratory's quality management plan. About Calibration Certificates and Verification Records: Based on the calibration certificates and verification records analyzed, opportunities for improvement were identified, as some inconsistencies were observed between the calibration plan of the remote laboratory and the certificates provided. In addition, there was a lack of information about the location of the remote laboratory where the equipment is located, in the revised certificates. On the execution of the laboratory tests: During the testifying of the tests the audit team showed that the laboratory of Vieto y Asociados performs the laboratory tests according to the procedures established in the corresponding test standards and good laboratory practices, except for the case of the theoretical maximum specific gravity determination test in which the use time of vacuum application (measured in the vacuum gauge) was greater than that established in the standard. However, after the visit to the laboratory, a time controller was incorporated.es
dc.publisherLaboratorio Nacional de Materiales y Modelos Estructurales (LanammeUCR)es
dc.subjectlaboratorioes
dc.subjectverificación de calidades
dc.subjectconservación viales
dc.subjectlaboratoryes
dc.subjectquality verificationes
dc.subjectroad conservationes
dc.titleAuditoría Técnica al laboratorio de Vieto y Asociados ubicado en la planta de Hernán Solís en Abangareses
dc.title.alternativeLM-PI-AT-012-17es
dc.typeinforme técnicoes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCRes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCR


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem