Mostrar el registro sencillo del ítem

dc.contributor.authorChaverri Jiménez, Jenny
dc.contributor.authorRodríguez Castro, Ellen
dc.contributor.authorCervantes Calvo, Víctor
dc.date.accessioned2018-04-27T14:58:05Z
dc.date.available2018-04-27T14:58:05Z
dc.date.issued2007-11
dc.identifier.urihttps://www.lanamme.ucr.ac.cr/repositorio/handle/50625112500/1125
dc.description.abstractEsta auditoría pudo evidenciar, que el laboratorio utiliza equipo que no es de su propiedad, en calidad de préstamo. Esto no le permite al laboratorio del MOPT tener pleno control sobre la gestión del mantenimiento, control, actividades de confirmación metrológica, reparación, entre otros. Además, no se dispone del certificado de calibración del equipo lo cual imposibilita realizar las correcciones y los ajustes necesarios para establecer la precisión y exactitud de las mediciones realizadas y de los resultados de ensayo derivados de las mismas. El laboratorio carece del equipo requerido por la normativa de referencia para realizar el ensayo de “Pruebas de compactación en sitio” tal como se solicita en el Cartel de Licitación. El proceso de verificación de calidad debe estar en la capacidad de poder corroborar los procesos constructivos y ensayos realizados por el contratista y su proceso de control de calidad, de acuerdo con lo que se establece en la normativa de referencia, con el propósito de realizar una verificación que caracterice de manera completa y suficiente los materiales que se incorporan al proyecto, en aras de garantizar la eficiencia y eficacia en la inversión de los recursos del Estado.es
dc.description.abstractThis audit could show that the laboratory uses equipment that is not its property, as a loan. This does not allow the MOPT laboratory to have full control over maintenance management, control, metrological confirmation activities, repair, among others. In addition, the equipment calibration certificate is not available, which makes it impossible to make the necessary corrections and adjustments to establish the precision and accuracy of the measurements made and the test results derived from them. The laboratory lacks the equipment required by the reference regulations to carry out the "On-site compaction tests" test as requested in the Bidding Poster. The process of quality verification must be able to corroborate the construction processes and tests carried out by the contractor and its quality control process, in accordance with what is established in the reference regulations, with the purpose of making a verification that fully and sufficiently characterizes the materials that are incorporated into the project, in order to guarantee efficiency and effectiveness in the investment of State resources.es
dc.language.isoeses
dc.publisherLaboratorio Nacional de Materiales y Modelos Estructurales (LanammeUCR)es
dc.subjectcompactaciónes
dc.subjectcontroles
dc.subjectmantenimientoes
dc.subjectcompactiones
dc.subjectcontroles
dc.subjectmaintenancees
dc.titleLABORATORIO DEL MOPT ENCARGADO DE LA VERIFICACIÓN DE CALIDAD UBICADO EN SANTA MARTA, PUERTO CARRILLO, GUANACASTE PROYECTO VIAL "MEJORAMIENTO DE LAS RUTAS NACIONALES N° 160, SECCIÓN PUERTO CARRILLO-ESTRADA Y N°158, SECCIÓN ESTRADA-LAJAS"es
dc.typeinforme técnicoes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCRes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCR