dc.description.abstract | Se realiza una visita de auditoría técnica de seguimiento a las instalaciones del laboratorio de control de calidad ubicado en la Planta de MECO, La Uruca, para observar el cumplimiento de las condiciones especificadas en los carteles de licitación LPCO-10-2001, LPCO-11-2001, LPCO-12-2001 y LPCO-18-2001 y sus respectivas aclaraciones. Debe asegurarse que los documentos que respalden la ejecución de las actividades de mantenimiento, comprobación intermedia o calibración de equipo reúnan la información suficiente que permita establecer la trazabilidad de las mediciones realizadas con los equipos de comparación o patrones. Se observó mejoras en este laboratorio, tomando como referencia la visitan realizada en setiembre de 2002. Estas mejoras se aprecian en la implementación de algunas bitácoras exigidas en los carteles de licitación. Sin embargo, estas bitácoras deben contener toda la información establecida en dichos carteles. | es |
dc.description.abstract | A follow-up technical audit visit is made to the facilities of the quality control laboratory located in the Plant of MECO, La Uruca, to observe compliance with the conditions specified in the tender posters LPCO-10-2001, LPCO-11-2001, LPCO-12-2001 and LPCO-18-2001 and their respective clarifications. It must be ensured that the documents supporting the execution of the maintenance activities, intermediate checking or calibration of team gather enough information to establish the traceability of measurements made with comparison equipment or patterns Improvements were observed in this laboratory, taking as reference the visit carried out in September 2002. These improvements can be seen in the Implementation of some logs required in the bidding posters. However, these logs must contain all the information established in such posters. | es |
dc.language.iso | es | es |
dc.publisher | Laboratorio Nacional de Materiales y Modelos Estructurales (LanammeUCR) | es |
dc.relation.ispartofseries | LM-PI-PV-AT-26-03 | |
dc.subject | mantenimiento | es |
dc.subject | calibración | es |
dc.subject | temperatura | es |
dc.subject | maintenance | es |
dc.subject | calibration | es |
dc.subject | temperature | es |
dc.title | Visita de seguimiento LGC ingeniería de pavimentos. Planta MECO, La Uruca | es |
dc.type | informe técnico | es |
dc.description.procedence | UCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCR | es |