Mostrar el registro sencillo del ítem

dc.contributor.authorBarrantes Jiménez, Roy
dc.contributor.authorMartínez Martínez, Oscar
dc.date.accessioned2018-04-23T19:25:52Z
dc.date.available2018-04-23T19:25:52Z
dc.date.issued2002-09
dc.identifier.urihttps://www.lanamme.ucr.ac.cr/repositorio/handle/50625112500/1081
dc.description.abstractEl presente informe presenta los resultados de la planta asfáltica de Santa Fe en Santa Clara, se realizan las observaciones siguientes: Certificación de buen funcionamiento de la planta En cuanto al control de humedad en los apilamientos hace falta una gestión profesional completa e inspección rigurosa de varios aspectos que afectan su funcionamiento adecuado y que afectan la producción de mezclas de suficiente uniformidad y de calidad asegurada. Aunado a esto, la falta de calibración del sistema de pesaje es también un problema mayor que no asegura a la Administración la recepción de la cantidad de mezcla que se ha pagado. Existe una ausencia de verificación de calidad y no hay una verificación de parte de la Administración para calcular el factor de pago según la calidad. Control de humedad en los apilamientos Donde se realiza bacheo y se colocan carpetas asfálticas se detectaron no conformidades que atentan contra la durabilidad del trabajo, no se hacen comprobaciones de la compactación ni se miden temperaturas con la frecuencia que se requiere para garantizar un buen proceso de colocación. Por las condiciones climáticas de lluvias intermitentes, no se da la debida atención a los drenajes para el agua de lluvia. Lo que representa un serio problema para el manejo y control de la humedad en los apilamientos de la planta, especialmente en la fracción fina , ya que obliga a mantener un estricto control en el contenido de humedad, habida cuenta que estos apilamientos no están bajo techo. La existencia de agua en la mezcla producida en un problema frecuente en esta planta por falta de atención al manejo y protección de los agregados.es
dc.description.abstractThis report presents the results of the Santa Fe asphalt plant in Santa Clara, the following observations were made: Certification of good functioning of the plant Regarding the moisture control in the stacking, professional management is needed, complete management and rigorous inspection of several aspects that affect its proper functioning are required and that affect the production of mixtures of uniformity and quality of assured quality. In addition to this, the lack of calibration of the weighing system is also a major problem that does not ensure the reception of the amount of mixture that has been paid. There is an absence of quality verification and there is no verification by the Administration to calculate the payment factor according to quality. Moisture control in the stacks Where they can make the patchy and place asphalt binders, there are not in accordance with the duration of the work, compaction tests are not done and the temperatures are not measured as often as required to guarantee a good placement process. Due to the climatic conditions of intermittent rains, due attention is not given to drainages for rainwater. This represents a serious problem for the management and control of moisture in the stacks of the plant, especially in the fine fraction, which requires strict control of the moisture content, which does not have any low ceiling. The existence of water in the mixture produced a frequent problem in this plant due to lack of attention to the management and protection of the aggregates.es
dc.language.isoeses
dc.publisherLaboratorio Nacional de Materiales y Modelos Estructurales (LanammeUCR)es
dc.relation.ispartofseries;LM-PI-PV-AT-01-02
dc.subjectasphalt mixtureses
dc.subjectraines
dc.subjectverificationes
dc.subjectmezclas asfálticases
dc.subjectlluviaes
dc.subjectverificaciónes
dc.titleConservación vial de la red de San Carlos LPCO 17- 01es
dc.typeinforme técnico
dc.typetechnical reporten
dc.typeinforme técnicoes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCRes
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::LanammeUCR


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem